Item Categories
Switch-Pro™ with Compact Level Control
#66 in  Liquid Level Controls or Instruments
-
Application
-
Offered in a type 6P enclosure with cable interface, the general purpose ultrasonic level transmitter provides continuous level measurement up to 32.8’ (10m) with a 4-20 mA signal output, and is configured via our free Webcal software. This non-contact liquid level sensor is ideally suited for corrosive, ultrapure, sticky or dirty liquids, and is broadly selected for bulk storage, day tank, lift station and process tank level applications.
-
-
Specifications
- Range
- LU27: 4” to 9.8’ (10cm to 3m)
- LU23: 8” to 18.0’ (20cm to 5.5m)
- LU28: 8” to 26.2’ (20cm to 8m)
- LU29: 8” to 32.8’ (20cm to 10m)
- Accuracy: ± 0.2% of range
- Resolution
- LU27: 0.019” (0.5mm)
- LU23: 0.039” (1mm)
- LU28/29: 0.079” (2mm)
- Dead band
- LU27: 4” (10cm)
- LU23/28/29: 8” (20cm)
- Beam width
- LU27: 2” (5cm)
- LU23/28/29: 3” (7.6cm)
- Configuration: WebCal® PC, Windows® USB 2.0
- Memory: Non-volatile
- Supply voltage: 24 VDC (loop)
- Consumption: 0.5W
- Loop resistance: 500 ohms @ 24 VDC
- Signal output: 4-20 mA, two-wire
- Signal invert: 4-20 mA or 20-4 mA
- Signal fail-safe: 4 mA, 20 mA, 21 mA, 22 mA or hold last
- Process temp.: F: -4º to 140º (C: -20º to 60º)
- Temp. comp.: Automatic
- Ambient temp.: F: -31º to 140º (C: -35º to 60º)
- Pressure: MWP = 30 PSI (2 bar)
- Enclosure rating: Type 6P, encapsulated, corrosion resistant & submersible
- Encl. material: Polycarbonate
- Trans. material: PVDF
- Cable jacket mat:Polyurethane
- Cable type: 4-conductor, shielded
- Cable length: 10’ (3m)
- Process mount
- LU27: 1” NPT (1” G)
- LU23/28/29: 2” NPT (2” G)
- Mount gasket: Viton®
- Classification: General purpose
- Compliance: CE, RoHS
- Approvals: cFMus
- Range
-
Features
- Offered in 4 measurement ranges from 9.8’ (3m) to 32.8’ (10m)
- DSP auto adaptive filters enable plug and play operation optimizing signal output filtering and obstacle recognition
- Submersible type 6P enclosure is ideal for sump and below grade installations
- Configuration is fast and easy via WebCal software and USB adapter
- Narrow 2” or 3” beam width for applications with limited measurement space
- Short 4” or 8” dead band maximizes the measurable filling capacity of the tank
- PVDF transducer and 6P polycarbonate enclosure for corrosive liquids
- Automatic temperature compensation for accurate measurement