back to list

+GF+ Signet Flow Instruments

8150 Battery Powered Flow Totalizer

signet flow 515

Data Sheet
User's Manual

The Signet 8150 Battery Operated Flow Totalizer is compatible with the Signet 515525 and 2517 flow sensors, and will provide years of dependable operation. The large digital display indicates flow rate and totalized flow volume simultaneously. One of the three totalizers is resettable from the front panel or a remote location, while the second resettable totalizer can only be reset by entering a user-selectable security code. Meanwhile, the third is a permanent non-resettable totalizer. Our intuitive software design and four-button keypad provide for simple operation while setting screen displays and programming the system. Calibration can be easily performed by entering the Auto-Cal feature and entering a value to match an external reference. Screen displays can be modified to suit the user's needs; along with the flow rate, any of the three totalizers can be selected as the displayed totalizer. Customers can quickly scroll through the totalizers simply by pressing any key on the keypad. A display averaging feature is included for applications where the flow in the pipe fluctuates. For applications where flow stops and starts due to production needs, a no-flow indicator will display the hours of non-flow. 

Features:

  • Three totalizers
  • Long-lasting lithium batteries
  • Mounting versatility
  • No-flow indicator
  • Large digital display with averaging
  • Simple push-button operation
  • User selectable access code prevents unwanted changes
  • Auto-calibration

Applications:

  • Wastewater Flow Accumulation
  • Water Treatment Systems
  • Remote or Mobile Treatment/Distribution Systems
  • Irrigation Systems
  • Filtration Systems
  • Commercial Pools & Spas
  • Groundwater Remediation
  • RO Concentrate
  • Process Flow Monitoring
  • UPW Distribution
  • Demineralizer Regeneration
  • Process Cooling Water
  • Neutralization Systems

 

 

8550 ProcessPro Flow Transmitter

signet flow 515

8550-1 Manual
8550-2 Manual
8550-3 Manual

The Signet 8550 Flow Transmitter is an advanced solution that converts the signal from all Signet flow sensors into a 4 to 20 mA signal for long distance transmission, and offers the unique feature of dual input and output capability. Configuration flexibility is maximized with two optional relays for process control, two packaging options for integral/pipe mount or panel installation, and scalability for virtually any flow range or engineering unit. State-of-the-art electronic design ensures long-term reliability, signal stability, and simple user setup and operation.

 

 

Features:

  • Permanent & resettable totalizers
  • Scaleable outputs
  • Relay options
  • Mounting versatility
  • Simulate function
  • 2 x 16 character dot matrix LCD
  • Chemical resistant enclosure and self-healing window
  • Large pushbuttons
  • Clearly marked terminal labels

Applications:

  • Flow control and monitoring
  • Filtration or softener regeneration
  • Effluent totalization
  • Pump protection
  • Feed pump pulsing
  • Ratio control
  • Water distribution
  • Leak detection

 

5075 ProPoint Totalizing Flow Monitor

signet flow 515

Data Sheet
User's Manual

The Signet 5075 Totalizing Flow Monitor displays flow rate on a highly visible analog dial, and uses a backlit LCD for displaying totalized flow volumes. One of the two totalizers is resettable from the front panel, and can also be reset from a remote location up to 30 m (100 ft.). The other totalizer is non-resettable and is commonly used to tally consumption, or to permanently record industrial effluent volumes. The monitors require 12 to 24 Volts, AC or DC, and can be used with any Signet Flow Sensor with a frequency output. Our intuitive software design and four-button keypad arrangement provide for simple operation, and the NEMA 4X/IP65 integrity of the front panel can be extended to the entire enclosure by using the optional Back Cover Kit.

Features:

  • Analog and Digital display
  • Two 8-digit Totalizers: one permanent, the other resettable
  • Tamper proof security code
  • Non-volatile memory
  • Intuitive Software Design
  • Simple push-button operation
  • Programmable pulse outputs
  • Versatile low voltage power requirement
  • 1/4 DIN, NEMA 4X/IP65 enclosure
  • Quality Standards: UL, CE

Applications:

  • Waste Water Flow Accumulation
  • Water Treatment Systems
  • Filtration Systems
  • Feed Pump Pulsing
  • Fertigation
  • Irrigation
  • Commercial Pools & Spas
  • Groundwater Remediation
  • HVAC
  • Process Flow Monitoring
  • UPW Distribution
  • Demineralizer Regeneration
  • Process Cooling Water
  • Neutralization Systems

 

5090 ProPoint Sensor Powered Flow Monitor

signet flow 515

Data Sheet
User's Manual

The Signet 5090 Sensor-Powered Flow Monitor is an economical analog flow rate indicator, with a meter movement powered by the output signal of Signet 515 Rotor-X and 319/515 Wet-Tap Flow Sensors themselves. No additional power source is required. This unique system is suitable for a wide range of flow rates, and is Factory Mutual (FM) approved for intrinsic safety without the need for barriers. The NEMA 4X/IP65 integrity of the front panel can be extended to the entire enclosure with the use of an optional Rear Cover Kit , adding to the independence and reliability of this simple flow measuring system, even in the most demanding industrial environments. 

Features:

  • Sensor-powered flow rate indication up to 60 m (200 feet) from sensor installation
  • Wide flow range: 1 to 20 fps in pipe sizes 0.5" to 36" (DN 15 to DN 900)
  • Wet-Tap optional
  • Single-point calibration from front panel
  • Quality Standards: FM, UL, CE
  • Factory Mutual (FM) approved for intrinsic safety in Classes I, II and III, Division I
  • High visibility analog display

Applications:

  • Filtration Systems
  • Hazardous Locations
  • Remote Flow Monitoring
  • Process Cooling Water
  • Distribution Systems
  • HVAC
  • Process Flow Monitoring

 

 

5500 ProPoint Flow Monitor

signet flow 515

Data Sheet
User's Manual

The Signet 5500 Flow Monitor is equipped with a scaleable 4 to 20 mA output and two relays programmable for high, low, and pulse operation. Instantaneous flow rate is easy to read on the analog dial, while the backlit LCD is used for calibration, set-up and displaying totalized flow volumes. One of the two totalizers is resettable from the front panel, and can also be reset from a remote location up to 30 m. (100 ft). The other totalizer is non-resettable and is commonly used to tally consumption, or to permanently record industrial effluent volumes. The monitors require 12 to 24 Volts, AC or DC, and can be used with any Signet Flow Sensor with a frequency output. Our intuitive software design and four-button keypad arrangement provide for simple operation, and the NEMA 4X/IP65 integrity of the front panel can be extended to the entire enclosure by using the optional Rear Cover Kit

Features:

  • Analog and Digital display
  • Two 8-digit Totalizers: one permanent, the other resettable
  • Two Programmable Relays
  • Fully Scaleable 4 to 20 mA Output
  • Tamper proof security code
  • Non-volatile memory
  • Intuitive Software Design
  • Simple push-button operation
  • Programmable pulse outputs
  • 1/4 DIN, NEMA 4X/IP65 enclosure
  • Quality Standards: UL, CE

Applications:

  • Waste Water Flow Accumulation
  • Water Treatment Systems
  • Filtration Systems
  • Feed Pump Pulsing
  • Fertigation
  • Irrigation
  • Commercial Pools & Spas
  • Groundwater Remediation
  • HVAC
  • Process Flow Monitoring
  • UPW Distribution
  • Demineralizer Regeneration
  • Process Cooling Water
  • Neutralization Systems

 

 

5600 ProPoint Batch Controller

signet flow 515

Data Sheet
User's Manual

The Signet 5600 Batch Controller is an extremely refined instrument that combines complex control capability with operational simplicity. Select either Simple or Advanced mode to limit feature options to suit your specific batch requirements, and make changes to batch volume quickly and easily. Two relays and one analog output provide the means to increase batch precision while dramatically reducing the possibility of water hammer in a system. Batch progress is displayed on the analog dial, while the backlit LCD is used for calibration, set-up, and to show totalized flow volumes. The controllers require 12 to 24 Volts, AC or DC, and can be used with any Signet Flow Sensor with a frequency output. The intuitive software design and four-button keypad arrangement is user friendly, and the NEMA 4X/IP65 integrity of the front panel can be extended to the entire enclosure by using the optional Rear Cover Kit.

Features:

  • Simple push-button operation
  • Intuitive Software Design
  • Easy Batch Volume Entry
  • Simple and Advanced operating modes
  • Remote Start, Stop & Resume
  • Auto-calibration
  • Two Stage Shutdown Control
  • Manual or Automatic Overrun Compensation
  • Estimates Time to Batch Completion
  • Overrun Alarm
  • Missing Signal Alarm
  • Advanced Valve Control
  • End-of-batch Trigger
  • Count-up or Count-down to Batch Completion
  • Dual Totalizers
  • Tamper-proof Security Code
  • Non-volatile memory
  • Versatile low voltage power requirement
  • 1/4 DIN, NEMA 4X/IP65 enclosure
  • Hard-coated, High Impact & UV resistant polycarbonate front face

Applications:

  • Batch Processes
  • Filter Backwash Initiation
  • Chemical Addition
  • Canning & Bottling

Comments
(Please login/register to leave a comment)
Back to Top